JA-150EM-DIN
- Specyfikacja techniczna
- Downloads
- Filmy
- Power supply: 230V/50 Hz, device of protection class II.
- Internal power consumption: approx. 0.1 W
- Operating frequency: 868 MHz
- Communication range: approx. 300 m (line of sight)
- IN input: low-voltage, galvanically separated from the mains
operating voltage 5 V
max. external voltage surge 30V DC
max. connection conductor length 3 m
- PU input: low-voltage, galvanically separated from the mains
-operating voltage 5 V
-max. external voltage surge 30V DC
-max. connection conductor length 3 m
-it is compatible with the impulse output of SO electric meters of class B
- TA input: input for the connection of load management control conductor, max. 230 VAC
- Dimensions: 68 × 96 × 18 mm, 1 DIN module
- Working environment: outdoor, protected, -20 to +60 °C
- Ingress protection class: front panel IP40 to EN 60529
- The product complies with: ETSI EN 300220, EN 50130-4 ed.2, EN 55022 and EN 60950-1
You are not logged in. You can only see our files after creating an account.